ENOVO - Everolimus Eluting Coronary Stent System

"Everolimus Eluting Coronary Stent on Cobalt Chromium L605 Platform mounted on Rapid Exchange Delivery System"
The Enovo Coronary Stent System includes loading and illusion of Everolimus Drug in a controlled fashion on L605 Cobalt Chromium (Co - Cr alloy) Platform, stent located on balloons catheter between two platinum iridium radio opaque markers bands. The drug is encapsulated with several biodegradable polymers and loaded on the stent through a proprietary coating technology. The Enovo is indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease in de novo coronary artery lesion in native coronary arteries with a reference vessel diameter of 2.50 mm to 4.0 mm and a lesion length 08 mm to 40 mm. The Enovo is intended for use in patients eligible for Percutaneous Transluminal Coronary Angioplasty (PTCA).
Endorser CrCo platform is engineering marvel with unique features to make navigation of the stent easy and safe even through even Challenging anatomy. It has unmet combination of radial strength, ease of the side branch access, vessel support and flexibility.
Hybrid Cell Design - Endorser CrCo is Hybrid cell design that has close cells at the end and open cells in middle.
Reduced injury of edges - Innovative hybrid design of Endorser inflation pressure of the balloon is evenly distributed even with uniform stent expansion. This reduces the "edge effect" of the stent.
Excellent side branch access - Link at every third crest in the middle segment that would usually face artery makes a clear wide opening for hardware to pass through in side branch.
Low bending stiffness (High Flexibility) - Attribute to the stent design and delivery system properties, the stent is highly flexible and easy to navigate difficult anatomy.

Technical Specification


No Title Description

1

Device Description

Everolimus drug with biodegradable polymer coating coronary stent system. Cobalt Chromium coronary stent platform.

2

Available Stent Length

8 mm,12 mm,16 mm, 20 mm, 24 mm, 28 mm, 32 mm , 36 mm , 40 mm

3

Available Stent Diameter

2.50 mm, 2.75 mm, 3.00 mm, 3.50 mm, 4.00 mm

4

Stent Material

Surgical grade L605 cobalt chromium alloy

5

Stent Design

Hybrid Stent has a unique hybrid cell design comprising of an intelligent mix of open and close cell designs resulting in a structure which provides excellent radial strength with a high degree of flexibility

6

Radio-opacity of struts

High

7

Radio-opacity of markers

Very High

8

Balloon Compliance

Semi-compliant

9

Entry Profile

0.01 mm

10

Catheter Compatibility

5 fr

11

Guide wire compatibility

0.014 mm

12

Balloon Winging

Tri-fold

13

Distal Tracking force

Low

14

Ballon Compliance

Semi-compliant

Ordering Information


DM 8 12 16 20 24 28 32 36 40

2.50

EN25008

EN25012

EN25016

EN25020

EN25024

EN25028

EN25032

EN25036

EN25040

2.75

EN27508

EN27512

EN27516

EN27520

EN27524

EN27528

EN27532

EN27536

EN27540

3.00

EN30008

EN30012

EN30016

EN30020

EN30024

EN30028

EN30032

EN30036

EN30040

3.50

EN35008

EN35012

EN35016

EN35020

EN35024

EN35028

EN35032

EN35036

EN35040

4.00

EN40008

EN40012

EN30016

EN40020

EN40024

EN40028

EN40032

EN40036

EN40040







Related Products

Our practice prides itself on providing the very finest level of service, from a simple filling to complex cosmetic dentistry.

  • Endorser SS316L Coronary Stent System
    stents

  • Endorser CrCo – Cobalt Chromium Coronary Stent
    stents

  • Sinew – Sirolimus Eluting Coronary Stent System
    stents

  • Inspire – Paclitaxel Eluting Coronary Stent System
    stents

Live Customizer

Choose Color-skin