SINEW - SIROLIMUS ELUTING CORONARY STENT SYSTEM

"New dimensions of strength of experience"
Sirolimus Eluting Coronary Stent on Cobalt Chromium L605 Platform mounted on Rapid Exchange delivery system.
The Sinew Coronary Stent System includes loading and illusion of Sirolimus Drug in a controlled fashion on L605 Cobalt Chromium (Co - Cr alloy) Platform, stent located on balloons catheter between two platinum iridium radio opaque markers bands. The drug is encapsulated with several biodegradable polymers and loaded on the stent through a proprietary coating technology. The Sinew is indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease in de novo coronary artery lesion in native coronary arteries with a reference vessel diameter of 2.50 mm to 4.0 mm and a lesion length 08 mm to 40 mm. The Sinew is intended for use in patients eligible for Percutaneous Transluminal Coronary Angioplasty (PTCA).
Endorser CrCo platform is engineering marvel with unique features to make navigation of the stent easy and safe even through even Challenging anatomy. It has unmet combination of radial strength, ease of the side branch access, vessel support and flexibility.
Hybrid Cell Design - Endorser CrCo is Hybrid cell design that has close cells at the end and open cells in middle.
Reduced injury of edges - Innovative hybrid design of Endorser inflation pressure of the balloon is evenly distributed even with uniform stent expansion. This reduces the "edge effect" of the stent.
Excellent side branch access - Link at every third crest in the middle segment that would usually face artery makes a clear wide opening for hardware to pass through in side branch.
Low bending stiffness (High Flexibility) - Attribute to the stent design and delivery system properties, the stent is highly flexible and easy to navigate difficult anatomy.

Technical Specification


No Title Description

1

Device Description

Sirolimus drug with biodegradable polymer coating coronary stent system. Cobalt Chromium coronary stent platform.

2

Available Stent Length

8 mm,12 mm,16 mm, 20 mm, 24 mm, 28 mm, 32 mm , 36 mm , 40 mm

3

Available Stent Diameter

2.50 mm, 2.75 mm, 3.00 mm, 3.50 mm, 4.00 mm

4

Stent Material

Surgical grade L605 cobalt chromium alloy

5

Stent Design

Hybrid Stent has a unique hybrid cell design comprising of an intelligent mix of open and close cell designs resulting in a structure which provides excellent radial strength with a high degree of flexibility

6

Radio-opacity of struts

High

7

Radio-opacity of markers

Very High

8

Ballon Compliance

Semi-compliant

9

Entry Profile

0.01 mm

10

Catheter Compatability

5 fr

11

Guide wire compatability

0.014 mm

12

Ballon Winging

Trifold

13

Distal Tracking force

Low

Ordering Information


DM 8 12 16 20 24 28 32 36 40

2.50

SN25008

SN25012

SN25016

SN25020

SN25024

SN25028

SN25032

SN25036

SN25040

2.75

SN27508

SN27512

SN27516

SN27520

SN27524

SN27528

SN27532

SN27536

SN27540

3.00

SN30008

SN30012

SN30016

SN30020

SN30024

SN30028

SN30032

SN30036

SN30040

3.50

SN35008

SN35012

SN35016

SN35020

SN35024

SN35028

SN35032

SN35036

SN35040

4.00

SN40008

SN40012

SN30016

SN40020

SN40024

SN40028

SN40032

SN40036

SN40040







Related Products

Our practice prides itself on providing the very finest level of service, from a simple filling to complex cosmetic dentistry.

  • Endorser SS316L Coronary Stent System
    stents

  • Endorser CrCo – Cobalt Chromium Coronary Stent
    stents

  • Enovo - Everolimus Eluting Coronary Stent System
    stents

  • Inspire – Paclitaxel Eluting Coronary Stent System
    stents